CNC Machine Tool Error Codes: Mori Seiki ZL-15~45 with M,MC,W/ MF-D6, MORIC-D6F
Use <Control+F> then type the alarm # you are looking for. Remember to use the same number format that is displayed on your machine (for example, EX0001, or EX001, or EX01)
EX0006, WRONG COMBINATION OF M-CODES, ALM0006, A7.5, Any wrong combination M-commands have been mistakenly given at the same time.
EX0013, M85-COMMAND WITH SPINDLE ON, ALM0013, A0.0, An M85 command has been given during spindle rotation or milling rotation.
EX0018, NEED ZERO-RETURN, ALM0018, A0.2, A cycle start has been activated without executing the X-axis and Z-axis zero returns after a machine lock cancel.
EX0019, WORK-COUNTER AT FULL COUNT, ALM0019, A0.3, A cycle start has been activated with the PC or external work counter at full count.
EX0020, EDITING SWITCH KEY IS ON, ALM0020, A0.4, A cycle start has been activated with the Editing Key Switch on.
EX0023, START INTERLOCK ON (EXT.), ALM0023, A0.5, The cycle operation has been started while an external start interlock signal has been input.
EX0024, CHUCK UMCLAMPED, ALM0023, A0.6, A cycle start has been activated with the chuck unclamped.
EX0026, DOOR NOT CLOSED, ALM0026, A0.7, The cycle operation has mistakenly been started without door closed.
EX0029, TAILSTOCK INCHING/ QUILL NOT OUT, ALM0029, A1.0, A cycle start has been activated during tailstock inching or with the tailstock quill not OUT.
EX0033, ONLY HANDLE MODE, ALM0033, A7.6, The jog push button has been pressed together with the O.T. release button after the hard O.T. limit switch has been tripped.
EX0064, AUTO-DOOR OPEN, ALM0064, A10.0, A auto-door closed detection signal has been deactivated without an auto-door close command having been given.
EX0068, SET UP MODE TIME OVER, ALM0068, A10.2, Door interlock cancel time has been over.
EX0069, DOOR LOCK CHECK TIME OVER, ALM0069, A10.3, Door lock complete signal has not been turned ON after elapsing the time set in timer.
EX0093, TAILSTOCK OUT PERMIT ERROR, ALM0093, A16.4, The tailstock quill OUT permission signal is abnormal. Check the monitor circuit.
EX0094, INTERRUPTION SIGNAL ON, ALM0094, A16.5, The motor interruption check signal is input at operation ready completion of each motor. Check the motor interruption circuit.
EX0095, TURRET ILLEGAL MOVEMENT, ALM0094, A16.6, The turret attempts to move without command. Check the turret output driver or clamp signal.
EX0096, INTERRUPTION FAILURE, ALM0096, A16.7, The motor interruption check signal is not input at operation ready completion of each motor. Check the motor interruption circuit.
EX0301, T-CODE COMMAND (#2), ALM0301, A7.7, An invalid T-command has been given. (Head2)
EX0302, T-CODE COMMAND (#1), ALM0302, A1.1, An invalid T-command has been given. (Head1)
EX0303, M17/M18-COMMAND BUT AUTROT = [1], ALM0303, A1.2, Either an M17 or M18 command has been given while the turret indexing short-path control is effective. (PC parameter AUTOROT= [1])
EX0305, TAILSTOCK UNCLAMPED (#2), ALM0305, A8.0, A T-command has been given with the tailstock umclamped. (Head2)
EX0312, NEED TURRET ZERO-RETURN, ALM0312, A1.3, A T-command has been given with the turret station not indexed to the correct position. Index the station manually.
EX0320, DURING POLYGON MODE, ALM0320, A1.4, A T-command has been given during polygon mode.
EX0322, TAILSTOCK UNCLAMPED, ALM0322, A1.5, An M3, M4, M13, M14 or M39 command has been given with the tailstock unclamp.
EX0324, TAILSTOCK UNCLAMPED (#1), ALM0324, A1.6, A T-command has been given with the tailstock unclamped. (Head1)
EX0332, TAILSTOCK NOTCONNECT POSITION, ALM0332, A1.7, An M79 command has been given with tailstock not in connecting position.
EX0333, TAILSTOCK INCHING/QUILL OUT, ALM0333, A2.0, An M78 or M79 command has been given with the tailstock quill OUT or in the inching state.
EX0334, TURRET PARAM. MUST BE 8, 10, 12, ALM0344, A2.1, A value other [8], [10], or [12] was input to the paramter as a setting for the number of turret station. Reset the parameter.
EX0350, PHASE-B SIGNAL NOT ON (#2), ALM0350, A12.1, The turret indexing phase-B count signal has not been activated. This error is caused when a phase-A signal is output twice in a row. Either the proximity switch for the phase-B counter is defective or it is improperly adjusted. (Head2).
EX0351, PHASE-A SIGNAL NOT ON, ALM0351, A14.0, The turret indexing phase-A count signal has not been activated. This error is caused when a phase-B signal is output twice in a row. Either the proximity switch for the phase-A counter is defective or it is improperly adjusted. (Head2)
EX0352, PHASE-B SIGNAL NOT ON (#1), ALM00352, A10.7, The turret indexing phase-B count signal has not been activated. This error is caused when a phase-A signal is output twice in a row. Either the proximity switch for the phase-B counter is defective or it is improperly adjusted. (Head1)
EX0353, PHASE-A SIGNAL NOT ON (#1), ALM0353, A11.0, The turret phase-A count signal has not been activated. This error is caused when a phase-B signal is output twice in a row. Either the proximity switch for the phase-A counter is defective or it is improperly adjusted. (Head1).
EX0354, PHASE-A NOT AGREE WITH PHASE-B (#2), ALM00354, A16.3, Current position data in the phase-A signal counter and the phase-B signal counter do not agree. Either the proximity switch for the counter is defective or it is improperly adjusted. (Head2)
EX0355, PHASE-A NOT AGREE WITH PHASE-B (#1), ALM0355, A11.1, Current-position data in the phase-A signal counter and the phase-B signal counter do not agree. Either the proximity switch for the counter is defective or it is improperly adjusted. (Head1)
EX0356, TURRET INDEX TIME UP (#2), ALM0356, A17.0, Turret indexing has not been completed within the specified time. (Head2)
EX0357, TURRET INDEX TIME UP (#1), ALM0357, A11.2, Turret indexing has not been completed within the specified.
EX0374, TOOL LIFE UP (#1), ALM0374, A11.3, Tool life up. (Head1)
EX0375, TOOL LIFE UP (#2), ALM0374, A17.1, Tool life up. (Head2)
EX0377, PHASE-A COUNTER ERROR, ALM0377, A11.4, Current value of phase-A counter is not [1] at pass though the turret home position during turret indexing.Either the home position detection switch or the phase-A count switch is defective or they are improperly adjusted. (Head1)
EX0378, PHASE-B COUNTER ERROR (#1), ALM0378, A11.5, Current value of phase-B counter is not [1] at pass though the turret home position during turret indexing. Either the home position detection switch or the phase-A count switch is defective or they are improperly adjusted.
EX0380, TAILSTOCK CLAMP/UNCLAMP TIME UP, ALM0380, A11.6, The tailstock clamp/unclamp operated has not been completed within the specified time.
EX0381, TAILSTOCK UNCLAMPED, ALM0381, A11.7, The clamp check signal has been deactivated with the tailstock was clamped. input.
EX0383, PHASE-A COUNTER ERROR (#2), ALM0383, A17.2, Current value of phase-A counter is not [1] at pass though the turret home position during turret indexing. Either the home position detection switch or the phase-A count switch is defective or they are improperly adjusted.(Head2)
EX0384, PHASE-B COUNTER ERROR (#2), ALM0384, A17.3, current value of phase-B counter is not [1] at pass though the turret home position during turret indexing. Either the home position detection switch or the phase -A count switch is defective or they are improperly adjusted. (Head2)
EX0386, NEED TURRET ZERO RETURN (#1), ALM0386, A12.0, The turret clamp check limit has been deactivated during cycle start. (Head1)
EX0393, NEED TURRET ZERO RETURN, ALM0393, A17.4, The turret clamp check limit switch has been deactivated during cycle start.
Ex0401, M3/M4/M13/M14 COMMAND ERROR, ALM0401, A2.2, Any of the following commands have been given improperly: M4; during normal spindle rotation M3; during reverse spindle roatation M14; during normal milling rotation or M13 during reverse milling rotation.
EX0404, M3/M4/M13/M14 ERROR; BAD S-CODE, ALM0405, A2.3, An M3, M13, or M14 command has been given either without given an S-code command after turning on the power or after giving an SO command.
EX0405, M41, M42, M43, M44 COMMAND MISSING, ALM0405, A2.4, An M3, M4 or M19 command has been given without giving either an M41, M42, M43, 0r M44 command.
EX0406, SPINDLE INTERLOCK SIGNAL ON, ALM0406, A2.5, An M3, M4 M13, M14, M19 or M39 command has been given while the external spindle interlock signal activated.
EX0407, BAD SPINDLE DIRECTION, ALM407, A2.6, The direction of spindle (or milling) rotation has been changed or while shifting the operation mode from automatic to manual, or from manual to automatic.
EX0410, M10/M11/W/ SPINDLE OR MILL ON, ALM0410, A2.7, An M10, M11 command has been given during spindle rotation or milling rotation.
EX0411, M3/M4-COM WITH SPINDLE JOG ON, ALM0411, A3.0, A M3, M4, or M39 command has been given during spindle jogging.
EX0412, M3/M4/M13/M14 W/ CHUCK UMCLAMP, ALM0412, A3.1, An M3, M4, M13, or M14 command has been given with the chuck unclamped.
EX0421, DURING TAILSTOCK INCHING, ALM0421, A3.2, A M3, M4, M13, or M14 command has been given during tailstock quill inching.
EX0429, M13/M14/M39 BUT MILLING JOG ON, ALM0429, A3.3, A M13, M14, or M39 command has been given during milling jogging.
EX0448, M-COM BUT NOT AT MILL STATION, ALM0448, A3.4, With the rotary tool station not indexed, either anM13, M14, M39 or M3, M4 during M90 command mode, command has been given.
EX0449, NOT MILLING STATION, ALM0449, A3.5, A G251 (polygon) command has been given at the position other than the milling stations.
EX0451, SPINDLE DRIVE UNIT ALARM, ALM0451, A12.1, The spindle drive unit alarm has been activated.
EX0453, MILL SPINDLE ALARM, ALM0453, A12.3, A milling amplifier alarm has been activated.
EX0456, SPINDLE INDEX TIME UP, ALM0456, A12.4, Spindle indexing has not been completed within the specified time.
EX0461, TAILSTOCK OUT SWITCH NOT ON, ALM0461, A12.5, The tailstock out check signal has been deactivated with the tailstock quill out.
EX0470, GEAR CHANGE TIME UP, ALM0470, A12.6, Gear change has not been completed within the specified time.
EX0471, GEAR CHECK LIMIT SWITCH NOT ON, ALM0471, A12.7, The gear check limit switch has been deactivated during spindle rotation.
EX0480, SPINDLE ORIENTATION TIME UP, ALM0480, A13.0, Spindle orientation has not been completed within the specified time.
EX0551, ELEC. CONTROL UNIT OVERHEATING, ALM0551, A13.1, Abnormal increase in electrical control unit temperature.
EX0554, OIL AIR PRESSURE STILL DOWN, ALM0554, A10.4, No increase in oil air pressure. Possible cause is broken piping or motor failure.
EX0560, AIR PRESSURE DROP, ALM0560, A13.2, Air pressure has dropped.
EX0561, OIL PRESSURE LOW, ALM0561, A13.3, Decrease in hydraulic pressure.
EX0562, LUBR. OIL PRESSURE STILL DOWN, ALM0562, A13.4, No increase in lubrication oil pressure. Possible cause is broken piping or motor failure.
EX0563, NO DROP IN LUBR. OIL PRESSURE, ALM0563, A13.5, Pressure has not decreased within the specified time after turning the cycle pump OFF. Possible cause is failure in the pressure switch or the magnet.
EX05564, NO DROP IN OIL AIR PRESSURE, ALM0564, A10.5, Pressure has not decreased within the specified time after turning the oil air pump OFF. Possible cause is failure in the pressure switch or the magnet.
EX0567, LUBRICATION WATCH DOG ALARM, ALM0567, A13.6, Lubrication pump pressure detection switch has not been activated within the specified time.
EX0570, INSUFFICIENT LUBRICATION OIL, ALM0570, A13.7, Insufficient lubrication oil.
EX0571, INSUFFICIENT OIL IN AIR, ALM0571, A10.6, Insufficient oil in oil air lubrication system.
EX0590, THERMAL TRIP, ALM0590, A10.1, One of the thermal relays in the auxiliary motor has been tripped.
EX0904, L-TURRET NOT AT Z ZERO RETURN, ALM0904, A8.1, The parts catcher OUT command has been given while the lower turret Z-axis is not zero-point.
EX0905, PRESETTER ARM DOWN, ALM0905, A8.2, The parts catcher OUT command has been given with the presetter arm rise check switch deactivated.
EX0907, PRESETTER ARM DOWN, ALM0907, A8.4, The presetter arm rise check switch has been deactivated while the parts catcher is out.
EX0911, NO MORE BAR STOCK, ALM0911, A3.7, Bar stock has run out.
EX0913, M71-COM WITH SPINDLE OR MILL ON, ALM0913, A4.0, An M71 command has been given during spindle rotation or milling rotation.
EX0915, NEED Z-AXIS ZERO-RETURN, ALM0915, A4.1, An M17 command has been given while X, Z axis at the zero point.
EX0916, PARTS CATHCER NOT HOME POSITION, ALM0916, A4.2, M71 or M85 command has been given while the parts catcher is not in the home position.
EX0922, M70-COMMAND BUT CHUCK CLAMPED, ALM0922, A4.3, An M70 command has been given while the chuck is clamped.
EX0923, SENSOR ON, ALM0923, A7.2, An M72 command has been given while sensor is turned on.
EX0942, SENSOR ARM OUT, ALM0942, A0.1, M3, M4 or T-code command is specified with extending the positioning sensor arm.
EX0945, ROBOT COMMAND ERROR, ALM0945, A4.4, ROBOT command has been given while the machine is not in home position.
EX0946, ROBOT ARM IN, ALM0946, A4.5, The following commands have been given while the ROBOT arm is moving IN. (M8, M3/4, M13/14, M38, M39, M71, M86, T-command)
EX0951, CONTACT BUT NO PRESET MODE, ALM0951, A14.2, The sensor has been activated without setting the presetter mode.
EX0952, CONTACT AS ARM RISES, ALM0952, A14.3, The sensor has been activated with the presetter ascending.
EX0953, ARM UP SIGNAL OFF IN AUTO MODE, ALM0953, A14.4, The presetter arm UP detection signal has been deactivated during automatic mode.
EX0956, TWO OR MORE SENSORS ARM ON, ALM0956, A14.5, Two sensors or more have been activated during presetter mode.
EX0957, PARTS CATCHER TIME UP, ALM0957, A14.6, The parts catcher operation has not been completed within the specified time.
EX0959, BARFEEDER EMG STOP, ALM0959, A14.7, The barfeeder is in emergency stop state.
EX0962, ROBOT CYCLE TIME UP, ALM0962, A15.0, ROBOT cycle has not been completed in the specified time.
EX0964, NO MORE WORKPIECES IN ROBOT, ALM0964, A15.1, On models equipped with a ROBOT, workpieces have run out.
EX0965, FULL PIECES IN ROBOT, ALM0965, A15.2, On models equipped with ROBOT, the ROBOT is completly full of workpieces.
EX0966, ROBOT ALARM, ALM0966, A15.3, The ROBOT alarm has been output.
EX0967, LOADER EMG STOP, ALM0967, A20.4, The loader state is in emergency stop state.
EX0968, NO MORE BAR STOCK, ALM0968, A15.4, Bar stock has run out.
EX0978, SENSOR ALARM, ALM0978, A17.5, Disconnection alarm is occured in the positioning sensor amplifier.
EX0979, CHUCK CLAMP TIME UP, ALM0979, A17.6, The chuck clamp operation has not been completed within the specified time when work seating check spec.
EX0999, SEQUENCE PROGRAM ERROR, ALM0999, A15.5, Abnormality in sequence program. Please contact your dealer.
EX1005, PUT IN THE NEW MATERIAL, ALM1005, A4.6, Please supply new work piece.
EX1024, DOOR MUST BE OPENED ONCE, ALM1024, A4.7, Open and close the door before starting new cycle.
EX1034, MUST BE POWER OFF, ALM1034, A7.3, Must be power off.
EX1035, MONITOR PARAMETER ALARM (#1), PER1035, A18.0, Parameter for load monitor function is improperly set. (#1)
EX1036, TEACHING ALARM (#1), PER1036, A18.1, Alarm occurs during teaching mode. (#1)
EX1037, SPINDLE OVERLOAD (#1), PER1037, A18.5, Spindle is overloaded. (#1)
EX1038, X-AXIS OVERLOAD (#1), PER1038, A18.6, X-axis is overloaded. (#1)
EX1040, Z-AXIS OVERLOAD (#1), PER1040, A18.7, Z-axis is overloaded. (#1)
EX1041, SPINDLE OVERLOAD (#2), PER1041, A19.5, Spindle is overloaded. (#2)
EX1042, X-AXIS OVERLOAD (#2), PER1042, A19.6,X-axis is overloaded. (#2)
EX1043, Z-AXIS OVERLOAD (#2), PER1043, A19.7, Z-axis is overloaded. (#2)
EX1044, MONITOR PARAMETER ALARM (#2), PER1044, A19.0, Parameter for load monitor function is improperly set.
EX1045, TEACHING ALARM (#2), PER1045, A19.1, Alarm occurs during teaching mode. (#2)
EX1047, MACHINE SPEC. PARAM. CLEARED, PER1047, A8.5, Parameter for machine spec. is improperly set.
EX1050, SPINDLE LOAD WARNING (#1), MER1050, A18.2, Spindle is overloaded warning level. (#1)
EX1051, X-AXIS LOAD WARNING (#1), MER1051, A18.3, X-axis is overloaded warning level. (#1)
EX1053, Z-AXIS LOAD WARNING (#1), MER1053, A18.4, Z-axis overload warning level. (#1)
EX1054, SPINDLE LOAD WARNING (#2), MER1054, A19.2, Spindle is overloaded warning level.
EX1055, X-AXIS LOAD WARNING (#2), MER1055, A19.3, X-axis is overloaded warning level. (#2)
EX1056, Z-AXIS LOAD WARNING (#2), MER1056, A19.4, Z-axis is overloaded warning level. (#2)
EX1067, DOOR CLOSE SIGNAL OFF, ALM1067, A2o.1, Auto-door close detection signal turns off.
EX1068, DOOR OPEN/CLOSE TIME OVER, ALM1068, A20.2, Auto door open or close detect single was not turned on within allowable time.
EX1069, DOOR SENSOR TEST ERROR, ALM1069, A20.3, Area sensor input signal (X1009.5) does not turn off.
EX1300, PRESETTER ARM NOT FULLY RAISED, ALM1300, A5.0, An M25 or M26 command has been given with the presetter arm not fully raised.
EX1301, TAILSTOCK UNCLAMPED, ALM1301, A5.1, An M25 M26 command has been given with the tailstock unclamped.
EX1302, TURRET INDEXING, ALM1302, A5.2, An M25, M26, or M79 command has been given during turret indexing.
EX1303, M25/M26 BUT SPINDLE ON, ALM1303, A5.3, An M25 or M26 command has been given during spindle rotation.
EX1304, M25/M26/M79 BUT MILLING ON, ALM1304, A5.4, An M25, M26, or M79 command has been given during milling tool rotation.
EX1409, M3/M4/M90 BUT SPINDLE INDEX MODE, ALM1409, A5.5, An M3, M4, or M90 command has been given during spindle indexing mode.
EX1416, M3/M4/M19 BUT SPINDLE BRAKE ON, ALM1416, A5.6, An M3, M4, or M19 command has been given with the spindle brake activated.
EX1417, M3/M4 BUT SPINDLE LOCKPIN OUT, ALM1416, A5.7, An M3 or M4 command has been given with the spindle indexing pin not at the [IN] state.
EX1419, NEED TURRET ZERO-RETURN, ALM1419, A6.0, When the turret station has been improperly indexed, either an M13/M14/ M39 command has been given or an M3/M4 command has been given under M90 command mode (with turret still improperly indexed).
EX1421, M13/M14 BUT SPINDLE BRAKE OFF, ALM1421, A6.1, An M13 or M14 command has been given with the spindle brake not activated.
EX1422, PRESETTER ARM NOT FULLY RAISED, ALM1422, A6.2, An M3, M4, M13, M14, or M39 command has been given with the presetter arm not fully raised.
EX1424, M-COMMAND BUT SPINDLE ON, ALM1424, A6.3, An M39, M40, M45, M68, M90, M91 or M312 command has been given during spindle rotation.
EX1426, M-COMMAND BUT MILL ON, ALM1426, A6.4, An M39, M46, M69, M90, or M91 command has been given during milling rotation.
EX1433, M-COMMAND BUT NOT TURNING MODE, ALM1433, A6.5, An M3, M4, or M19 command has been given while not in turning mode.
EX1435, NOT MILLING OR TURNING MODE, ALM1435, A6.6, An M13, M14, or M39 command has been given while neither in milling mode nor turning mode.
EX1442, M39/M45/M68 DURING M90 MODE, ALM1442, A6.7, An M39, M45, 0r M68 command has been given during M90 (spindle/milling synchronized operation).
EX1444, M-COM BUT NOT IN TURNING MODE, ALM1444, A7.0, An M40, M41, M42, M43, M44, or M90 command has been given while not in turning mode.
EX1451, C-AXIS OFF WHILE SPINDLE ON, ALM1451, A15.6, C-axis connection cancel detection has been deactivated during spindle rotation.
EX1452, C-AXIS CONNECTION TIME UP, ALM1452, A15.7, C-axis connection time is up.
EX1456, C-AXIS CONNECT OFF: C-AXIS ON, ALM1456, A16.0, C-axis connection detection has been deactivated during C-axis connection.
EX1457, OIL COOLER ALARM, ALM1457, A16.1, Oil cooler is overloaded or oil temperature is abnormal.
EX1458, MILLING HOLDER JOIN TIME UP, ALM1458, A16.2, Milling holder has not joined to the drive within the specified time.
EX1921, M/S/T CODE IN SAME BLOCK, ALM1921, A7.1, M85/86 command and T/S-code command have been given in the same block. Specify M85/86 in a single block.
EX1924, M39/ T-CODE IN SAME BLOCK, ALM1924, A7.4, Both an M39 command and a T-code command have been in same block. Specify M39 in a single block.
EX1928, DOOR NOT CLOSED, ALM1928, A3.6, Shutter open/close command has been given while the front door is not closed.
EX1936, CHUCK UNCLAMP, ALM1936, A08.0, An forkardt chuck index command has been given with the chuck unclamped.
EX1937, SPINDLE ON, ALM1937, A08.1, An forkardt chuck index command has been given during spindle rotation.
EX1938, FORKARDT CHUCK NOT HOME POSITION, ALM1938, A08.2, Forkardt chuck index command has been given while the forkardt chuck is not in home position.
EX1958, ROBOT POWER NOT TURNED ON, ALM1958, A17.7, Robot power is not turned ON.
EX2027, NC ON OPERATING, ALM2027, A08.6, Interlock ket switch was turned to release side during automatic cycle or feed hold.
EX2028, PUSH SINGLE BLOCK SW. ON, ALM2028, A08.7, Cycle start button was pressed at single block OFF status.
EX2029, CYCLE START NOT PERMITTED, ALM2029, A09.0, Single block was turned off or door was opened during automatic cycle.
EX2033, DOOR SENSOR DETECT, ALM2033, A09.7, Area sensor detects obstacles after specifying auto-door close command.
Check out www.fanucmanual.com for our CNC troubleshooting book
For Machine Tool Parts and Accessories, go to www.globalmachineparts.com
Free cnc repair and troublshooting info at www.pinpointcncblog.com
For information on Toyooki products, go to www.toyookivalve.blogspot.com
Go to www.industrialfanslink.com for information on Industrial Fans for Machines.
For machine scraping, alignment and repair check out Geometric Specialties
Go to www.industrialoilcooler.com for information on Industrial Oil Coolers and Chillers
Looking for New and Used Fanuc Parts? Go to www.fanucshop.com
Filed Under Mori Seiki | Leave a Comment
CNC Machine Tool Error Codes: Mori Seiki SL-150~300 with MSC-518 TC/MSD-518 TC
Use <Control+F> then type the alarm # you are looking for. Remember to use the same number format that is displayed on your machine (for example, EX0001, or EX001, or EX01)
EX0013, SPINDLE OR ROTARY TOOL SPINDLE ON, A4.5, An auto door open command has been given during spindle or rotary tool spindle rotation.
EX0016, TAILSTOCK IS NOT CLAMPED, A11.0, A cycle start has been activated with the tailstock not clamped.
EX0018, ALL-AXES NEED ZERO RETURN, A0.0 A cycle start has been activated without the all-axes zer0-returns after a machine lock cancel.
EX0019, WORK COUNTER AT FULL COUNT, A0.1, A cycle start has been activated with the PC or external work counter at full count.
EX0020, EDITING KEY SWITCH IS ON, A0.2, A cycle start has been activated with Editing Key Switch on.
EX0023, START INTERLOCK SIGNAL ON, A0.3, A cycle start has been activated while while an external start interlock signal has been input.
EX0024, CHUCK IS NOT CLAMPED, A0.4, A cycle start has been activated with the chuck is not clamped.
EX0026, PLEASE CLOSED THE DOOR, A5.7, A cycle start has been activated without the door closed. Close the door.
EX0029, TAILSTOCK QUILL IS NOT OUT, A11.1, A cycle start has been activated during tailstock inching or with the tailstock spindle not OUT.
EX0035, CUT OFF INCOMPLETE, A4.1, Cut off has not been completed.
EX0068, INTERLOCK RELEASE TIME OVER, A13.0, Door interlock cancel state has been invalid.
EX0069, DOOR LOCK TIME OVER, A14.0, Door lock complete signal has not been turned ON after elapsing the time set on timer.
EX0079, SPINDLE ORT. CIRCUIT ABNORMAL, A19.4, Spindle circle orientation detection circuit is abnormal. Though orientation has been held detection signal is not on. Though orientation has not been held, detection signal is not off.
EX0089, SPEED DETECTION CIRCUIT IS ABNORMAL, A7.5, Speed dectection signal of monitor circuit is abnormal. Though spindle or rotary tool spindle has not been rotated, speed detection signal is on. Though spindle or rotary tool spindle has been rotating over fixed speed, speed dectection signal is off.
EX0097, PANEL I/O ALARM, A2.7, An I/O alarm has been occured in the flat type operation panel.
EX0099, PANEL ALARM, A5.6, An alarm has been occurred in the flat type operation panel.
EX0302, IMPROPER T-CODE COMMAND ERROR, A6.0, A T-command out of turret station number has been given.
EX0303, TURRET SHORT-PATH INDEX MODE, A0.7, During turret short-path index mode, turret forward reverse is commanded.
EX0320, POLYGON MODE, A15.0, A T-command has been given during polygon mode.
EX0357, TURRET INDEX TIME OVER, A6.2, Turret indexing has not been completed within the specified time.
EX0322, TAILSTOCK IS NOT CLAMPED, A11.2, A spindle forward/reverse, rotary tool spindle forward/reverse, rigid tap mode command has been given while the tailstock is not clamped.
EX0324, TAILSTOCK IS NOT CLAMPED, A11.3, A T-command has been given while the tailstock is not clamped.
EX0333, TAILSTOCK QUILL IS OUT, A10.1, A tailstock clamp/ unclamp command, tailstock forward/ backward command has been given with the tailstock spindle out or inching state.
EX0374, TOOL LIFE ENDING, A7.1, Tool life ending.
EX0380, TAILSTOCK CLAMP/ UNCLAMP TIME OVER, A19.5, The tailstock clamp/unclamp operation has not been completed within the specified time.
EX0381, TAILSTOCK CLAMP SIGNAL OFF, A6.3, The clamp check signal has been deactivated with the tailstock was clamped.
EX0386, TURRET NEED ZERO RETURN, A0.6, The turret clamp check limit switch has been deactivated during cycle start.
EX0395, TURRET INPOSITION CHECK ERROR, A8.3, Turret inposition check is turned off for 5 seconds.
EX0401, SPINDLE OR ROTARY TOOL SPINDLE ON, A1.1, Spindle/ rotary tool spindle reverse command has been given during their forward rotation or spindle/ rotary tool spindle forward command has been given during their reverse rotation.
EX0404, S-CODE IS NOT COMMANDED, A1.2, A spindle forward/ reverse, rotary tool spindle forward/ reverse command has been given either without given an S-code command after turning on the power or after giving an SO command.
EX0406, SPINDLE INTERLOCK SIGNAL ON, A1.3, A spindle forward/reverse, spindle orientation, synchronous operation on, rotary tool spindle forward/ reverse, rotary tool spindle orientation, rigid tap mode on command has been given while the external spindle interlock signal activated.
EX0407, SP. /R T. SP. DIRECTION INCORRECT, A1.4, The direction of spindle or rotary tool spindle rotation has been changed or while shifting the operation mode from automatic to manual, or from manual, to automatic.
EX0410, SPINDLE OR ROTARY TOOL SPINDLE ON, A1.5, A chuck open/close command has been given during spindle or or rotary tool spindle rotation.
EX0411, SPINDLE JOG ON, A1.6, A spindle forward/reverse, spindle orientation, synchronous operation on command has been given during spindle jogging.
EX0412, CHUCK IS NOT CLAMPED, A1.7, A spindle forward/ reverse, rotary tool spindle forward/ reverse, rigid tap mode command has been given with the chuck is not clamped.
EX0421, TAILSTOCK IS IN INCHING MODE, A10.4, A spindle forward/reverse, rotary tool spindle forward/reverse, rigid tap mode command has been given during tailstock spindle inching.
EX0428, R. T. SP. INTERLOCK SIGNAL ON, A2.0, A rotary tool spindle forward/ reverse, rigid tap mode command has been given while the external rotary tool spindle interlock signal activated.
EX0429, ROTARY TOOL SPINDLE JOG ON, A2.1, A rotary tool spindle forward/reverse, rigid tap mode, rotary tool spindle orientation command has been given during rotary tool spindle jogging.
EX0451, SPINDLE DRIVE UNIT ALARM, A7.3, The spindle drive unit alarm has been activated.
EX0457, SPINDLE DRIVE UNIT ALARM #2, A9.3, The headstock 2 spindle drive unit alarm has been activated.
EX0461, TAILSTOCK OUT SWITCH IS ABNORMAL, A7.4, The tailstock out check signal has been deactivated with the tailstock spindle out.
EX0490, SPINDLE SPEED ABNORMAL, A19.6, Spindle speed abnormality has been detected, Please check the following. Parameter setting is not correct. Spindle unit is abnormal.
EX0551, ELECTRICAL CABINET OVER HEAT, A3.1, Excess heat in electrical control unit. Check unit and filter.
EX0560, AIR PRESSURE LOW, A16.2, Air pressure has dropped.
EX0561, HYDRAULIC PRESSURE LOW, A3.3, Hydraulic pressure has dropped.
EX0562, LUBRICANT PRESSURE LOW, A4.4, Lubrication oil pressure has not increased. Possible cause is broken piping or motor failure.
EX0563, LUBRICANT PRESSURE HIGH, A3.5, Lubrication oil has not decreased within the specified time after turning the cycle pump OFF. Possible cause is failure in the pressure switch or the magnet.
EX0567, LUBRICANT WATCH DOG ALARM, A3.6, Lubrication pump pressure detection switch has not been activated within the specified time.
EX0570, LUBRICANT OIL LEVEL LOW, A3.7, Insufficient lubricant oil. Add oil as necessary. (Message)
EX0599, LUBRICANT OIL EMPTY, A10.6, Shortage of lubrication oil. Add oil as necessary. (Error)
EX0910, PLEASE CLOSED THE DOOR, A2.2, A parts catcher OUT command has been given while the door is not closed.
EX0913, SPINDLE OR ROTARY TOOL SPINDLE ON, A15.2, A auto presetter arm down command has been given during spindle or rotary tool spindle rotation.
EX0914, TOOL PRESETTER ARM DOWN, A10.3, The parts catcher OUT command has been given while the headstock 2 presetter arm dose not rise.
EX0915, X, Z-AXIS NEED ZERO RETURN, A15.3, An auto presetter arm down command has been given while X, Z-axis is not at the zero point.
EX0916, PARTS CATCHER NOT HOME POSITION, A11.6, Auto presetter arm down, auto door open/close, tailstock unclamp command has been given while the parts catcher is not in the home position.
EX0922, CHUCK IS CLAMPED, A5.0, Bar feeder command has been given during chuck clamped.
EX0923, TOOL PRESETTER SENSOR ON, A15.4, An auto presetter arm rise command has been given while the sensor is ON.
EX0930, OPTION ALARM 1, A23.0, Alarm in special design. Refer to the accompanying documents for the special design.
EX0931, OPTION ALARM 2, A23.1, Alarm in special design. Refer to the accompanying documents for the special design.
EX0932, OPTION ALARM3, A23.2, Alarm in special design. Refer to the accompanying documents for the special design.
EX0933, OPTION ALARM 4, A23.3, Alarm in special design. Refer to the accompanying documents for the special design.
EX0934, OPTION ALARM 5, A23.4, Alarm in special design. Refer to the accompanying documents for the special design.
EX0935, OPTION ALARM 6, A23.5, Alarm in special design. Refer to the accompanying documents for the special design.
EX0936, OPTION ALARM 7, A23.6, Alarm in special design. Refer to the accompanying documents for the special design.
EX0937, OPTION ALARM 8, A23.7, Alarm in special design. Refer to the accompanying documents for the special design.
EX0945, ROBOT/LOADER COMMAND ERROR, A12.7, ROBOT/LOADER command has been given while the machine is not in home position.
EX0946, ROBOT/LOADER ARM IN, A11.4, T-code, coolant on, auto presetter arm down, spindle forward/reverse, rotary tool spindle forward/reverse, rotary tool connection check command has been given while robot/loader arm is moving in.
EX0951, TOOL PRESETTER SENSOR ON, A12.0, The sensor has been activated without setting the presetter mode.
EX0953, TOOL PRESETTER SENSOR ON, A12.1, The sensor has been activated with the presetter arm rising.
EX0953, TOOL PRS. ARM DOWN IN AUTO MODE, A12.2, The presetter arm rise dectection signal has been deactivated during automatic mode.
EX0956, TWO OR MORE SENSORS ON SAME TIME, A12.3, Two sensors or more have been activated during presetter mode.
EX0959, BAR FEEDER EMG. STOP SIGNAL ON, A5.1, Bar feeder is in emergency stop state.
EX0962, ROBOT/LOADER CYCLE TIME OVER, A13.3, ROBOT/LOADER cycle has not been completed in the specified time.
EX0964, MATERIAL IN ROBOT/LOADER EMPTY, A12.6, On models equipped with a robot/loader, workpieces have run out.
EX0966, ROBOT/LOADER ALARM SIGNAL ON, A11.5, The robot/loader alarm has been output.
EX0968, BAR IN STOCK EMPTY, A5.2, On the mode equipped with one piece bar feeder, bar stock has run out.
EX0979, WORK SEATING SIGNAL TIME OVER, A12.5, The chuck clamp operation has not been completed within the specified time when workpiece holding detection specification.
EX0980, OPTION ALARM 21, A24.o, Alarm in special design. Refer to the accompanying documents for the special design.
EX0981, OPTION ALARM 22, A24.1, Alarm in special design. Refer to the accompanying documents for the special design.
EX0982, OPTION ALARM 23, A24.2, Alarm in special design. Refer to the accompanying documents for the special design.
EX0983, OPTION ALARM 24, A24.3, Alarm in special design. Refer to the accompanying documents for the special design.
EX0984, OPTION ALARM 25, A24.4, Alarm in special design. Refer to the accompanying documents for the special design.
EX0985, OPTION ALARM 26, A24.5, Alarm in special design. Refer to the accompanying documents for the special design.
EX0986, OPTION ALARM 27, A24.6, Alarm in special design. Refer to the accompanying documents for the special design.
EX0987, OPTION ALARM 28, A24.7, Alarm in special design. Refer to the accompanying documents for the special design.
EX0999, SEQUENCE PROGRAM ABNORMAL, A4.2, Abnormality in sequence program. Contact Mori Seiki.
EX1005, PLEASE SUPPLY THE NEW MATERIAL, A5.3, A cycle start has been activated when the bar stock runs out. Put the new stock. (one piece bar feeder)
EX1024, PLEASE OPEN THE DOOR ONCE, A14.1, The door has never been opened after executing M02 or M3o command. Open and close the door before starting new cycle.
EX1034, POWER MUST BE OFF, A15.1, After turning off the power once, turn it on again.
EX1035, LOAD MONITOR PARAMETER ERROR, A18.0, Parameter for load monitor function is improperly set.
EX1036, ALARM AT TEACHING MODE, A18.1, Alarm occurs during teaching mode.
EX1037, SPINDLE OVERLOAD, A18.5, Spindle is overloaded.
EX1038, X-AXIS OVERLOAD, A18.6, X-axis is overloaded.
EX1040, Z-AXIS OVERLOAD, A18.7, Z-axis is overloaded.
EX1041, SPINDLE OVERLOAD, A21.2, Spindle is overloaded.
EX1047, SPECIFIED PC PARAMETER CLEARED, A16.1, Parameter for machine specification is improperly set.
EX1050, SPINDLE LOAD WARNING, A18.2, Spindle is overloaded warning level.
EX1051, X-AXIS LOAD WARNING, A18.3, X-axis is overloaded warning level.
EX1053, Z-AXIS LOAD WARNING, A18.4, Z-axis is overloaded warning level.
EX1054, SPINDLE LOAD WARNING, A21.5, Spindle is overloaded warning level.
EX1058, C-AXIS LOAD WARNING, A19.1, C-axis is overloaded warning level.
EX1059, B-AXIS LOAD WARNING, A21.0, B-axis is overloaded warning level.
EX1061, MOTOR INTERRUPTION IS ABNORMAL, A13.1, Spindle & servo motor shut off check signal error (time over). Shut off check signal is ON though power is not OFF at power supply. Shut off check signal is OFF though power is OFF at power supply. Shut off check signal is OFF though power is OFF at normal operation.
EX1064, WORK NUMBER PARITY ERROR, A16.3, Work number search signal is disconnected.
EX1067, AUTO DOOR IS OPENED, A6.6, Auto door close detection signal has turned off.
EX1068, AUTO DOOR OPEN/CLOSE TIME OVER, A6.7, Auto door open or close detection signal has not been turned on within the specified time.
EX1079, COMMAND TIME OVER, A21.7, The one of following commands has not been completed within the specified time. <Commands (spindle 1,2 and chuck 1,2) spindle rotation or orientation, spindle stop, phase or speed synchronous ON/OFF, rotary tool spindle rotation or orientation, chuck clamp/umclamp, C-axis connection, C-axis rerease, spindle brake clamp/unclamp, work unload, tailstock spindle IN/OUT, automatic tool presetter arm UP/DOWN, parts catcher IN/OUT, ceiling shutter open/close, forkardt chuck index>
EX1080, X, Y-AXIS NEED ZERO RETURN, A17.6, Manually return X, Y-axis to the zero point.
EX1081, LOAD MONITOR WARNING, A19.3, Cutting load was over alarm level during load monitoring.
EX1082, LOAD MONITOR WARNING, A19.2, Cutting load was over warningl level during load monitoring.
EX1300, TOOL PRESETTER ARM DOWN, A7.2, A tailstock out/in command, or tailstock forward/unclamp command has been given with the presetter arm not fully raised.
EX1301, TAILSTOCK IS UNCLAMPED, A9.1, A tailstock out/in command, or auto tool presetter down command has been given with the tailstock umclamped.
EX1302, TURRET ROTATING, A9.2, A tailstock out/in/unclamp command, steady rest open/close command, or tailstock forward/backward command has been given during turret indexing.
EX1303, SPINDLE ON, A9.4, A tailstock out/in command, steady rest open/close command, tailstock forward/backward command, or tailstock unclamp command has been given during spindle rotation.
EX1304, SPINDLE OR ROTARY TOOL SPINDLE ON, A9.5, A tailstock out/ in command, tailstock unclamp command, tailstock forward/backward, or steady rest open/close command has been given during rotary tool spindle tool rotation.
EX1310, IMPROPER CONNECTION POSITION, A9.6, The joint position of tailstock and steady rest is not last clamp position. Check the last clamp position data and Z-axis position data.
E1416, SPINDLE BRAKE ON, A9.7, A spindle forward/ reverse, spindle orientation, rigid tap mode command has been given with the spindle brake activated.
EX1421, PLEASE SELECT MILLING MODE, A11.7, A rotary tool spindle forward/reverse rotary tool spindle orientation, rigid tap mode has been given with the spindle brake not activated.
EZ1422, TOOL PRESETTER ARM MODE, A12.4, A spindle forward/reverse, rotary tool spindle forward/reverse, rotary tool connection check, C-axis connection, sychronous operation, rigid tap mode command has been given with the presetter arm not fully raised.
EX1424, SPINDLE ON, A2.4, A C-axis connection, spindle brake clamp, gear neutral, spindle/ rotary tool spindle rotation mode on/off, rotary tool connection check, or sensor arm out command has been given during spindle rotation.
EX1426, ROTARY TOOL SPINDLE ON, A2.5, A spindle brake unclamp, C-axis connection cancel, spindle/rotary tool spindle rotation mode on/off, or rigid tap mode command has been given during rotary tool spindle rotation.
EX1429, BOTH SPINDLE ROTATION NOT SAME, A4.6, The spindle rotational direction specified by turret 1 does not agree with that of the turret 2 during synchronous operation.
EX1433, PLEASE SELECT SP. TURNING MODE, A13.4, A spindle forward/reverse, spindle orientation, or synchronous operation, rigid tap mode command has been given while not in the turning mode.
EX1442, SIMULTANEOUS SPINDLE/R. T. SP. MODE, A2.6, During simultaneous spindle/ rotary tool spindle operation mode, C-axis connection spindle clamp brake, rotary tool connection check command has been given.
EX1444, PLEASE SELECT SP. TURING MODE, A13.6, A gear change, spindle/ rotary tool spindle rotation mode command has been given while not in the turning mode.
EX1447, RIGID TAP MODE, A16.4, T-code, rotary tool spindle forward/ reverse, rotary tool spindle orientation, spindle forward/reverse, synchronous command has been given during rigid tap mode.
EX1457, OIL COOLER ALARM, A3.0, Oil cooler is overloaded or oil temperature is abnormal.
EX1465, NOT IN SYNCHRONOUS MODE, A17.1, During synchronous mode, synchronous revolution is abnormal.
EX1557, COOLANT FLOW TOO LOW, A13.2, Abnormality in flowing coolant.
EX1586, OIL FILTER ALARM, A17.5, Oil filter of chuck has been stopped. Please change oil filter.
EX1590, CHUCK CLAMP SIGNAL TIME OVER, A20.2, When an M-command for chuck clamp has been given, chuck has not clamped within the specified time.
EX1591, CHUCK CLAMP SIGNAL OFF, A20.3, A chuck clamp check signal has been deactivated without a chuck unclamp command having been given.
EX1592, CHUCK CLAMP/ UNCLAMP SIG. FAILURE, A20.4, Two chuck stroke detection switches have been deactivated.
EX1921, M/S/T-CODE IN SAME BLOCK, A14.7, Auto door open/close command and T/S-command have been given in the same block. Specify auto door open/close command in a single block.
EX1928, PLEASE CLOSED THE DOOR, A17.7, Ceiling shutter open/ close command has been given while the front door is not closed.
EX1934, AIR PRESSURE LOW, A17.2, Air pressure has dropped.
EX1963, SENSOR BATTERY ALARM, A7.6, Touch sensor battery alarm.
EX1970, CYCLE START ON FROM ROBOT/LOADER, A17.3, A cycle start has been activated by robot/loader during automatic operation.
EX1971, MEASURING SENSOR ABNORMAL, A7.7, Touch sensor is abnormal.
EX1975, ST. REST CLAMP SIGNAL OFF, A19.7, The steady rest clamp signal has been deactivated without a steady rest unclamp command having been given.
EX1977, PARTS CATCHER CYCLE TIME OVER, A21.6, A parts catcher cycle has not been completed within the specified time.
EX1978, WORK HOLDING SIGNAL OFF, A17.4, The workpiece holding detection signal was turned OFF though the chuck unclamp command was not executed.
EX1979, RETRACT TOOL FROM SENSOR, A19.0, The sensor has been activated without setting the presetter mode.
EX2027, NC OPERATING ON, A0.5, Interlock key switch was turned to release side during automatic cycle or feed hold.
EX2028, PLEASE PRESS SINGLE BLOCK SWITCH, A6.1, A cycle start has been activated at single block OFF status.
EX2029, CYCLE START PERMISSION IMPERFECT, A6.5, Single block has been turned off or front door has been opened during automatic cycle.
EX2033, DOOR SENSOR DETECTS OBSTACLES, A14.4, Door sensor detects obstacles after specifying auto door close command.
EX2057, SHUT TRAY COVER FOR PARTS CATCHER, A5.4, A parts catcher out command has been given while the tray cover for parts catcher is not closed.
EX2405, SPINDLE OR ROTARY TOOL SPINDLE ON, A13.5, Ceiling shutter open command has been given during spindle or rotary tool spindle rotation.
EX2419, CHUCK IS CLAMPED #2, A10.2, Synchronous command has been given during headstock 2 chuck unclamped.
EX2550, THERMAL OVERLOAD TRIP 1, A20.2, The thermal relay of the following auxiliary unit motor has tripped. (hydraulic unit pump motor, chip coolant pump motor, shower coolant pump motor, lubricant oil pump motor)
EX2551, THERMAL OVERLOAD TRIP 2, A20.1, The thermal relay of the following auxiliary unit motor has tripped. (coolant pump motor).
EX2909, DOOR IS OPENING, A16.5, When the power is turned on by weekly timer, the front door is not closed.
EX2917, RETRACT PARTS CATCHER, A5.5, When the power is turned on by weekly timer, retract the parts catcher in the tray cover.
EX2918, SENSOR BEING TOUCHED, A16.0, M87 or M88 command has been given while sensor is being touched.
EX2919, CHECK OFFSET DATA, A13.7, During tool presetter mode, detachable tool presetter (D.T.P) was installed or removed. Offset data may be renewed by installing or removing D.T.P during tool presetter mode. Check the offset data.
EX2920, AXIS POSITION IMPERFECT, A10.0, Parts catcher command has not been accepted by incorrect axis position. Please move X axis to zero return point. Please move B axis out of parts catcher interference position.
E2940, OPTION ALARM 41, A8.6, Alarm in special design. Refer to the accompanying documents for the special design.
EX2941, OPTION ALARM 42, A8.7, Alarm in special design. Refer to the accompanying documents for the special design.
EX4002, OPEN THE DOOR THEN CLOSE, A16.6, After turning on the power, open the door once, and close again.
EX4003, DOOR INTERLOCK RELEASED, A20.5, Door lock is specified while the door interlock keo switch is released.
EX4004, PLEASE CLOSE THE DOOR, A20.6, Door lock is specified while door is opened.
EX4006, DOOR INTERLOCK RELEASED, A16.7, A cycle start has been activated with the door interlock key switch is released.
EX4007, DOOR INTERLOCK NOT RELEASED, A15.7, After the door interlock function state is cancelled, door interlock function state is cancelled, door interlock function is released again before monitor circuit becomes normal.
EX4008, C-AXIS OVERLOAD, A15.6, C-axis is overloaded.
EX4009, RETRACT PARTS CATCHER, A15.5, After turning on the power, retract the parts catcher in the tray cover.
EX4014, SPINDLE OFF MODE, A14.6, A cycle start has been activated during spindle off mode.
EX4015, B-AXIS OVERLOAD, A21.3, B-axis is overloaded.
EX4018, CEILING SHUTTER IS OPEN, A14.5, A spindle forward/reverse rotation, rotary tool spindle forward/reverse rotation command has been given, when the ceiling shutter is open.
EX4024, CHUCK IS NOT CLAMPED, A17.0, A turret select change command has been given, when rotary tool spindle is rotated.
EX4025, PARTS CATCHER CYCLE ON, A4.7, The spindle 2 rotation or orientation, or the chuck 2 clamp/unclamp command has been given during parts catcher cycle.
EX4030, Y-AXIS NEED ZERO RETURN, A14.3, Spindle forward/reverse or, spindle orientation command has been given without at Y-axis zero point.
EX4403, SPINDLE ON, A20.7, Rigid tap mode has been commanded during synchronous mode.
Check out www.fanucmanual.com for our CNC troubleshooting book
For Machine Tool Parts and Accessories, go to www.globalmachineparts.com
Free cnc repair and troublshooting info at www.pinpointcncblog.com
For information on Toyooki products, go to www.toyookivalve.blogspot.com
Go to www.industrialfanslink.com for information on Industrial Fans for Machines.
For machine scraping, alignment and repair check out Geometric Specialties
Go to www.industrialoilcooler.com for information on Industrial Oil Coolers and Chillers
Looking for New and Used Fanuc Parts? Go to www.fanucshop.com
Filed Under Mori Seiki | Leave a Comment
« go back — keep looking »